Technical Parameters of TCK wire rope monitoring system
System Default Parameters:
1. Sensitivity: >1.5V/mT
2. Sampling frequency response: ≤8kHz
3. System working voltage:AC220V±10%(explosion-proof)、AC127V±10%(explosion-proof)
4. System rated power capability: <200W
System Performance Parameters
5. Positioning inspection resolution :1mm;
6. Uncertainty rate of quantitative inspection (P):<1%
7. Maximum value of vibration range of wire rope:L=(Inner diameter of testing head-diameter of wire rope)×0.8/2
8. Accuracy rate:
100% For limiting value defects: Detectability = 100%
>99% For dangerous value defects: Detectability = 99%
>95% For normal value defects: Detectability > 95%
>70% For minor value defects: Detectability > 70%
Minor defects: actual defect value is less than 30% of the discard value;
Normal defects: actual defect value is more than 30%, but less than 60% of the discard value; which will not affect the safety of wire rope
Dangerous defects: actual defect value is more than 60%, but less than 90% of the discard value; which will affect the safety of wire rope gradually
Limiting defects: actual defect value is more than 90% of the discard value; which will affect the safety of wire rope directly
System Applicability Parameters:
9. Inspection range of rope Diameter,
Inspection Range for Model 65:φ16 ~56mm;
Inspection Range for Model 95:φ20 ~80mm
10. Testing Speed: V = 0-13m/s
11. Distance for signal transferring:
length of cable connected:≤80m(extendingto 1KM with relay station 1km)
length of optical fiber cable connected:≤10 km
12. Dimension between ropes: <φ175mm x1200mm
13. Working environmental temperature:-20℃—+40℃
14. Degree for dust-proof and water-proof:IP54