System Default Parameters

1. Sensitivity >1.5V/mT

2. Sampling frequency response:  ≤8kHz

3. System working voltageAC220V±10%explosion-proof)、AC127V±10%explosion-proof

4. System rated power capability <200W

System Performance Parameters

5. Positioning inspection resolution 1mm

6. Uncertainty rate of quantitative inspection (P):<1%

7. Maximum value of vibration range of wire ropeL=Inner diameter of testing head-diameter of wire rope×0.8/2

8. Accuracy rate:

100% For limiting value defects: Detectability = 100%

99% For dangerous value defects: Detectability = 99%

95% For normal value defects: Detectability > 95%

70% For minor value defects: Detectability > 70%

          Minor defects: actual defect value is less than 30% of the discard value;

          Normal defects: actual defect value is more than 30%, but less than 60% of the discard value; which will not affect the safety of wire rope

         Dangerous defects: actual defect value is more than 60%, but less than 90% of the discard value; which will affect the safety of wire rope gradually

          Limiting defects: actual defect value is more than 90% of the discard value; which will affect the safety of wire rope directly

System Applicability Parameters:

9. Inspection range of rope Diameter,

Inspection Range for Model 65φ16 56mm

Inspection Range for Model 95φ20 80mm

10. Testing Speed    V  = 013m/s

11.  Distance for signal transferring

     length of cable connected≤80mextendingto 1KM with relay station 1km

     length of optical fiber cable connected≤10 km

12. Dimension between ropes <φ175mm x1200mm

13. Working environmental temperature-20—+40

14. Degree for dust-proof and water-proofIP54